Sequential timers are electronic control units used to manage the pulsing sequence of solenoid valves in pulse jet dust collector systems. These timers control the cleaning cycle by turning valves on and off at precise intervals, optimizing bag cleaning, airflow, and energy usage. Available in various channel configurations, these timers are compatible with both Rotex and Manik valve systems and are critical for ensuring consistent and automated filtration operation.
Parameter | Range / Details |
---|---|
Available Channels | 6, 10, 12, 16, 20, 24 |
Timing Range | On-time: 10 ms – 999 ms, Off-time: 1 – 60 sec (adjustable) |
Voltage Input | 230V AC (standard), 24V/110V AC options available |
Output Type | Relay / Triac based outputs for solenoid control |
Display | LED indicators for channel status |
Enclosure | MS powder-coated or plastic (optional) |
Compatibility | Works with Rotex, Manik, and other solenoid valves |